One of the best investments you can make in your commercial building is the installation of a fire sprinkler system. A properly designed sprinkler system can greatly reduce your exposure to loss of property and lives from fires.

That same system can also reduce your property insurance costs. However, installing the sprinkler system is just the beginning. Just like specialized machinery used in a manufacturing process, sprinkler systems need regular inspection, maintenance, and testing in order to function at their full potential.

To help ensure your sprinkler system performs properly in the event of a fire, these basic maintenance and inspection requirements should be followed:

10 Steps For Maintaining Your Fire Sprinkler System

Test Every 5 Years 

1. Complete an internal pipe exam every five years. The purpose of this test is to inspect for the presence of foreign materials that might obstruct the flow of water from through the pipes to the sprinklers. Follow the full inspection process here.

2. Test or replace pressure gauges in comparison with a calibrated gauge. Those deemed not to be accurate within the standard scale reading must be recalibrated or replaced. (Explore these scales and requirements here.)

Get insights like this right in your inbox. Subscribe to the Central Blog below.

Test Every Year

3. Complete an annual flow test. This includes testing to ensure water flow detecting devices are operational, and that a signal is properly triggered when you allow the water to flow for 60 seconds. Follow the full testing process here.

4. Visually inspect piping on an annual basis to ensure the system is in operating condition and free of physical damage. 

5. Perform an annual visual inspection of the fire department connection to be sure the caps have not been removed. If the caps have been removed, debris or insects may build nests in the connection, resulting in obstructions in the system during sprinkler head operations. 

6. Visually inspect sprinkler heads annually. Heads over 50 years old (especially those manufactured before 1920) should be replaced or a representative sample of heads should be sent to a recognized laboratory for testing. If one head were to fail testing, all heads in the representative area should be replaced. Testing is then required every ten years.

Test Every Quarter

7. Test alarms quarterly. To do this, communicate with your local fire department or central station and warn them you will be testing these systems. Then trigger activation of alarms through the running of water through the inspector test valve, and confirm whether or not the alarm sounds.

Test Every Week

8. Visually inspect the control valves on a weekly basis. This includes ensuring that the valves are open and secured, and confirming there are no visible leaks in the equipment.

9. Ensure all storage is at least 18-inches below sprinkler heads in order to prevent interference with the spray of water from a sprinkler head during a fire.

Check As Often As Desired

10. Reference the full and comprehensive list of testing and maintenance requirements from the NFPA 25 to ensure your system is up-to-date.

Keep In Mind: All testing should be performed by qualified personnel, preferably a licensed and insured sprinkler fire protection contractor. Always keep sprinkler design and testing paperwork onsite to allow easy access for contractors, insurance carrier loss control representatives, and insurance property rate promulgation companies such as Verisk. 

The Central Difference

Central Insurance was first founded as a fire insurance company in 1876 and, as such, has an ongoing vested interest in fire safety. Our loss control consultants are trained to evaluate the basic adequacy of sprinkler systems, and are happy to address any concerns as part of the general survey process for Commercial Property Insurance policyholders. 

Not already covered by Central? Find an independent Central agent today to get a quote. 

The information above is of a general nature and your policy and coverages provided may differ from the examples provided. Please read your policy in its entirety to determine your actual coverage available.

3 responses to “10 Steps for Maintaining Your Fire Sprinkler System”

  1. Our sprinkler system has recently started malfunctioning. My husband has been manually watering the grass the past few mornings since the heads aren’t spitting enough water to cover the entire lawn. I like that you said that all testing should be carried out by professionals, ideally a sprinkler fire protection contractor that is certified and insured. Always retain sprinkler design and testing documentation on site so that contractors, insurance carrier loss control agents, and insurance property rate promulgation businesses may easily access it. We’ll book an appointment with a trustworthy service this weekend as per your advice. Thanks!

  2. It makes sense to perform a weekly visual inspection of the control valves. This involves, as you said above, making sure the valves are open and fastened as well as making sure the apparatus is free of any obvious leaks. I’ll tell my husband about this because we want to operate a restaurant someday and think it’s fantastic. For the protection of both us and our patrons, I am aware that a good restaurant kitchen fire suppression system will be necessary.

    1. Central Insurance Avatar
      Central Insurance

      Thanks so much for your comment, Lily! We’re glad to hear that you find these tips helpful.

      And we wish you the best of luck on your journey to open your own restaurant—that’s an incredible goal! When the time comes, feel free to get in touch with one of our agents if you need any help determining types of coverage you’ll need for your space!

Leave a Reply

Blog at WordPress.com.

Discover more from Central Insurance Blog

Subscribe now to keep reading and get access to the full archive.

Continue reading